6-2 Easy Controller manual

This manual page is for our 6-2 easy controller, which allows you to control:



Jump to

Front panel description
Rear panel description
Parameters
WiFi and Output configuration/set
WiFi
Output connectors description
Output driver settings
PTT IN and OUT
Principle of USED LED
OTRSP - USB protocol for SO2R
Remote control
QUICK setup
QUICK setup - manual way
Controller IP address
Access to web User interface (UI)
IP access to the UI
Configuration page
After configuration page

Product details


Front panel description

6-2 easy controller description front panel qro.cz hamparts.shop

1. & 2. Buttons TRX A and TRX B

- Press buttons with LED, ports 1 to 6 for each TRX (A and B)

3. Used status LED

- Indication of antenna collision or no antenna selected

4. PTT LED

- PTT indication for TRX A and TRX B


Rear panel description

6-2 easy controller description rear panel classic version qro.cz hamparts.shop

1. Output to ANT switch

- Output DB15 female connector - outputs A and B, Vext etc.

2. Output to ANT switch

- Outputs RJ45, one for each bank (A and B)

3. PTT RCA

- PTT IN and OUT for each TRX and PA

4. GND screw

- There are high voltage protections - to work right, please, connect GND to the common ground point

5. Power supply input DC

- DC 13.8 V input

6. USB - OTRSP/FW

- USB port - RFI filter, OTRSP protocol, FW upload

7. WIFI 2.4 GHz

- SMA for 2.4 GHz WiFi antenna


Parameters

- DC supply voltage: 13.8 V DC plug
- DC current supply:
 max. 1.5 A
- DC Vext supply:
 max. 26 V (pin 7 Vext + only for relay output)
- DC Vext current:
 max. 1 A (pin 7 Vext + only for relay output) 
- Output is universal: +13.8 V or + EXT or to GND (depends on drivers and jumpers)
- Outputs 2x6 or BCD

- BCD output is DC supply voltage or Vext one
- Output current:
 max. 500mA per output, 500mA total/bank
TBD driver is included
- Voltage drop for TBD driver:
 typ. 0.2V for +13.8 V input and 0.7 V including fuse
- Voltage drop for ULN driver: typ. 0.8V for +13.8 V input
- RFI filtered USB port, compatible with OTRSP protocol
- WiFi 2.4 GHz CLIENT with external antenna (SMA at rear panel)
- WiFi 2.4 GHz b/g/n compatible
- Web-based remote control
- WiFi SSID and password configuration by the WEB page
- PTT hot switch protection PTT (TX = GND)
- TRX A-B lock (first win) cannot set the same antenna
- USED LED and PTT IN/OUT
 protection while NO ANT or locked one

IMPORTANT NOTE: Default output setting is with TBD driver. Output control is +12V. If you need to control external devices by switching to ground, you must replace the driver with ULN and change the Jumper settings. ULN driver is NOT included. You can buy it here.

DC plug cable qro.cz hamparts.shop


WiFi and Output configuration/set

You can switch WiFi ON and OFF and also outputs between classic 6x2 or the BCD by the front panel buttons while the controller is started up. If you do not use remote control, it is recommended to switch WiFi OFF.

easy controller connector d-sub 15 female qro.cz hamparts.shop

1. Buttons

- 1A = WiFi disabled
- 1B = WiFi enabled

3. Buttons

- 2A = Outputs A and B are BCD
- 2B = Outputs A and B are classic 6x2

If you like to change these settings, you have to:
- Disconnect controller from power supply
- Press and hold button you need (example: button 1A for disable WiFi)
- Hold the button and connect power supply
- Wait 5 seconds and release button
- Restart controller by disconnecting and connecting power supply


WiFi

There is 2.4 GHz WiFi client build-in. When you do not need remote web control, please disable it. When you like to use it, you need to enable it and setup AP SSID and password.

- When the WiFi is enabled and you switch ON the controller, you will hear relay clicking + LED blinking. It means that the controller is trying to connect to WiFi AP. If there is no WiFi configured or no AP available, controller tries it 20 times (20x clicking and LED blinking).
- When it fails to connect to WiFi, the client switches to AP mode and waits for configuration.
- You will find a WiFi called remoteAP now. Connect to it. Password will be: qrocz599
- Please, before the connecting we recommend to switch off another internet Connection at the device you would like to use for connecting. Like LTE at mobile device, LAN at notebook etc.
- If you managed to connect to remoteAP, open a web browser and go to: http://192.168.100.39:59/qroconfig?p=xxqro
- You will see a simple page SSID: and pwd: → use your credentials (Your WiFi settings - SSID (name) and password) and click on send.
- The correct answer of the server will be "Your wish is my command"
- Device is restarting and using you credentials. You should see/hear just 2-3 USED LED flashes/relay clicking and it will be connected to the WiFi (not 20 times any more)
- You can continue to Remote Control notes.

 TIP: Resetting the user/pwd manually: http://<ip_address_of_your_switch>:59/qroconfig?p=xxqro&r=666

   Example: You setup your Easy controller, it got the IP address 192.168.0.34.
To reset the pwd: http://192.168.0.34:59/qroconfig?p=xxqro&r=666.
If you change your wifi (or reset the pwd), the controller will always go into AP-Mode. So you need to bring your wifi back or give the controller new credentials.
If you ever need to reset your pwd when the controller is in AP-Mode: http://192.168.100.39:59/qroconfig?p=xxqro&r=666

Output connectors description

There are three output connectors where you can connect antenna switch (band pass filters etc.). DB15 and both RJ45 are almost the same. You can buy RJ45 LAN cable all over the world, what is big advantage. DB15 has got possibility to apply external supply voltage - in the case you use relays with different voltage from 12V DC or BCD output with TTL logic (Vext = 5 V).

Controller also allows to use positive DC voltage out or switching outputs to the ground. Our 6-to-2 (six-2-two) RF switches need +12 V to switch ports on. If you have your own one with different relay voltage (24 V), you can connect this different voltage (24 V) to Vext PIN (7 at DB15) and change jumper settings in the controller. If you have your own switch with activating relays to ground, you have to change internal drivers and set the jumpers to the right position. You can find more info in this manual.

6-2 easy controller output connectors description qro.cz hamparts.shop

OUTPUTS = outputs pins to RF switch. Could be +12 V (or Vext) or to ground - depends on driver inside.
Vext = External voltage input. You can use this when you use relays with different voltage from +12 V.
Vdrv = voltage at driver. Connect it to the supply voltage of relays when you use switching to ground - this enables internal protection diodes in the output driver.

6-2 easy controller connection BCD matrix table qro.cz hamparts.shop

BCD OUTPUTS. Following BCD matrix table. Output could be again supply voltage, Vext (24 V or 5 V for TTL BCD output) or switching to ground.


Output driver settings

IMPORTANT NOTE: PLEASE, before you change the settings, you need to change the output driver and jumper settings. This can only be changed when the controller is switched off. Never turn on the controller when you have the opposite jumper and output driver settings.

Outputs for switch control are universal. Output can be either + supply voltage, +Vext voltage or switching to ground. Either 2x6 or BCD.

6-2 easy controller output table qro.cz hamparts.shop

6-2 easy controller jumpers qro.cz hamparts.shop

6-2 easy controller jumpers qro.cz hamparts.shop

6-2 easy controller jumpers qro.cz hamparts.shop

6-2 easy controller relay connection qro.cz hamparts.shop

PTT IN and OUT

PTT is very important thing there. Controller has got PTT HOT switch protection - when PTT is in transmitting, you are not able to switch port. Web User Interface does have PTT indicator too.

There are relay contacts between PTT IN and OUT. When the controller is switched OFF, PTT OUT is disconnected from IN. The same when NO port is selected. PTT IN and OUT is connected together only when any port is selected (PTT A and bank A, PTT B for bank B). This is protection between TRX and PA where the PA is keyed only when some antenna is selected.

Principle of USED LED

LED indicator USED is connected with PTT control. When LED USED is ON, PTT OUT is disconnected from PTT IN. This is protection for PA - NO antenna connected = PA does not have PTT.

You can switch off all ports for bank A or B by pressing any button two times. Also, if there is NO Band assigned to a port in OTRSP, the controller unassigns the last selected port and illuminated the USED LED. It also disconnects the PTT input to output. Web based User Interface does have the same function as classic buttons at the controller.

There is no feedback from controller to the OTRSP and logging software (only one way communication). In this case USED is a protection against selecting the same antenna port at both TRX (A and B). There is the First Win, but when you select some port by the web UI or button and then the logging software has no idea about it. This is a protection that disconnects the PTT OUT in case the same port that is already used by the first TRX is selected.

OTRSP - USB protocol for SO2R

The Open Two Radio Switching Protocol (OTRSP) is a simple set of commands and events for computer control of a Single Operator Two Radio (SO2R) device.
Link: https://www.k1xm.org/OTRSP/

There, the controller does have only one way communication - listens to commands from the PC.

 NOTE: If the Band is not assigned to a port, the controller unassigns the last selected port and illuminates the USED LED. It also disconnects the PTT input to output.

You can use this protocol for automatic control from a logging program (N1MM, DX log, Win-test, etc.). For proper operation you must connect a USB cable between the controller and PC. You need to find the correct assigned port number in the PC - com port name: USB-SERIAL CH340 and number.

6-2 easy controller manual qro.cz hamparts.shop

Then set this port number in the logging program. The default setting is SPEED 9600 and 8N1.

N1MM software:

- Go to configuration, select the correct port number
- check CW/Other and open Set
- Under Two Radio Protocol, select OTRSP
- The other settings depend on your configuration - for example Radio Nr. 2 for S02R

6-2 easy controller n1mm qro.cz hamparts.shop
In the Configured window, select the Antenna tab.

6-2 easy controller n1mm qro.cz hamparts.shop
Here the Code means the number of the button on the controller (1 to 6), Antenna is the name used in N1MM and Band is the frequency band used for the button at controller = ports at antenna switch. In this example: 160m band will select port 1 (button 1) at controller. 10m port 6 etc.

Win-test of DX log software:

- The procedure for these loggers is similar to N1MM. In the configuration you have to select the correct com port and OTRSP protocol

Either use the default settings button or manually set the OTRSP to 9600 8 N 1.

6-2 easy controller n1mm qro.cz hamparts.shop

6-2 easy controller n1mm qro.cz hamparts.shop

6-2 easy controller n1mm qro.cz hamparts.shop

6-2 easy controller n1mm qro.cz hamparts.shop

The difference from N1MM is the configuration of the antenna port number and the appropriate band. Win-test and DX log use bit code interpretation.

6-2 easy controller n1mm qro.cz hamparts.shop

6-2 easy controller n1mm qro.cz hamparts.shop

6-2 easy controller n1mm qro.cz hamparts.shop

6-2 easy controller n1mm qro.cz hamparts.shop

Where Pin numbers are bit number for each TRX: pin 1 to 4 are 4 bits for TRX A (AUX1) and bits 5 to 8 for TRX B (AUX2).

6-2 easy controller bcd table qro.cz hamparts.shop

Where bit A in table is pin 1, B pin 2 etc. For TRX B it is A = pin 5, B = pin 6 etc.
Example: controller/antenna port 4 will be 0 0 1 0, pin1 = 0, pin2 = 0, pin3 = 1, pin4 = 0

You can use any band to any output - as you need.


Remote Control

There is WiFi 2.4 GHz client in the controller. You have to set up WiFi Connection to your WiFi AP (router). Remote control is based on web page with User Interface (UI) looking like front panel of the Easy Controller. You are able to change buttons labels, color, size etc.

6-2 easy controller user interface qro.cz hamparts.shop

QUICK setup

Mike DM5XX has prepared Entry Point and Easy Assistant pages. This is the best way to go, see all possibilities of our UIs.
Please, start with ENTRY POINT manual page
QUICK UI setup link is there: EASY ASSIST
Please, follow our YouTube channel

IMPORTANT NOTE: We recommend a VPN while using remote access from outside your network in general.

QUICK setup manual way

1. Find IP address of the controller in your LAN

2. Open link in your web browser (select right one by the controller version

- 6-2 controller: http://logic.qro.cz/logic/EasyControl/index6by2.htmll

3. You should see web UI. Please, close warning with Websocket error (you have to set right IP address)

4. Open config and fill in your controller's IP address

5. Press update

6. You can update all you need as ANT name, font size etc. Again, press update button

7. Go to bottom of the page and press Generate link

8. Press Open from link - you will have new window with updated parameters which should work and you can control the controller

9. Save this link somewhere - you can use it from any device in LAN

10. Good to know

- Take care that your link starts with "http://" (not https! Some Browsers like Chrome add this automatically)
- If you changed something on the config page, please always press "update" on that Field. Create link after you completed everything
- Always use VPN. Never use and trust Portforwarding. Please see:
https://uk.pcmag.com/vpn/93737/how-to-set-up-and-use-a-vpn or
https://www.hellotech.com/guide/for/how-to-port-forward
- Ask a friend who has knowledge of setting up VPN (or Portforwarding). Since this is specific to your router or internet setup, we cannot help you there a lot.



Controller IP address

This controller is configured as DHCP client - looking for IP address from DHCP server (usually your home internet router).

At first, you have to find IP address of your device. There are more ways how to do it:

1. Find IP in your router:

- log in to your router and look at DHCP leases table (Host Name should be Impero)

2. IP addresses scanner software:

- use any IP address scanner software, for example Advanced Port Scanner

There you should be able to find IP address with Port 59 - this is your device

easy controller advanced port scanner how to find ip address qro.cz hamparts.shop

Access to web User Interface (UI)

There is web UI a tour server which is called by your browser. The advantage is that you don't have to do any updates. We do it for you and you just use your web browser to call up the latest version.

There are two ways to call web User Iterface:

1. Use UI files from our server

When your router allows it, you can try:
http://sixbytwo.local:59/index?customizeurl=logic.qro.cz/logic/Manager/6by2_v2/&jsurl=logic.qro.cz/logic/Manager/6by2_v2/rl/

2. Direct call of the controller IP (in local network)

http://logic.qro.cz/logic/EasyControl/index6by2.html?id=qro.cz&ip=IP%3Aport

where IP is address of the controller and port (default 59).
example: example:http://logic.qro.cz/logic/EasyControl/index6by2.html?id=qro.cz&ip=192.168.198.176%3A59

You can also call just the web UI and configure IP address in the configuration part:
http://logic.qro.cz/logic/EasyControl/index6by2.html

IP access to the UI

There are more ways to access to the UI web page.

1. Only LAN network

When you are only in your local LAN network - controller and devices which control it - then you can use only your local IP address which you have find before (like 192.168.99.54:59 etc.).

2. Controller in local network - access from internet

The controller is in local network and you would like to access to it from internet.

Not secure way is Port Forwarding done in your router. You have to have Public IP address on it! Please, have a look at your router manual and set port forwarding. You have to set: public port at your public IP address to local IP address and local port (like 192.168.99.54 port 59 in our example).

3. VPN

Security way is VPN - this is question of your router and another home network/PC/tablet/mobile phone. Secured VPN is highly recommended for most access to your local network.



Configuration page

This is configuration web page where you can set ID, IP address, Labels, font size, color and port parameters.

easy controller configuration qro.cz hamparts.shop

- URL of controller: IP_address:port, example: 192.168.99.54:59
- Controller Labels: Labels for antenna ports
- Offset: Setting offset of Labels - you can center it as you like



After configuration page

1. Click at the button: Generate Link
- This link you can use for any web browsers in the same network (VPN)
2. Click at the button: Open from link
- This will open new web browser window with the last configuration
- It is recommended to press Ctrl + F5 to refresh everything to the last changes
- Check small status LED at UI web - must blink when you press any button at UI

Generated link includes IP address and port of the controller in your local network (LAN). You are able to access into it only from the same network, routed network or VPN. When you use Port Forwarding at your router - you have to use your router's public IP and port you set for forwarding. When you are back in your LAN, please use local IP settings.

Product details

Included in package

Controller assembled and tested
DC plug cable - image
USB cable - image
WiFi omni directional antenna 6 dBi - image
DB15 male connector with cover

Box dimensions (mm) 165x110x55 mm - al box
Weight brutto (kg) 0.62 kg

Manufacturer:

Ing. Jan Šustr
ID 05476356, VAT CZ8407024780
Palachova 1777/7, 591 01 Žďár nad Sázavou, Czech republic, Europe

General instructions:

Please also read general instructions before handling the product.

European Union Declaration of Conformity

Manufacturer Ing. Jan Šustr (QRO.cz):

ID 05476356, VAT CZ8407024780
Palachova 1777/7, 591 01 Žďár nad Sázavou, Czech republic, Europe

declares that the assembled product:

6-2 EASY CONTROLLER

is compatible with the relevant Union harmonisation legislation directives:
EMC Directive 2014/30/EU
ČSN EN 61000-6-3 ed. 2
ČSN EN 61000-6-1 ed. 2 (333432)

On behalf of Ing. Jan Šustr (QRO.cz)
Ing. Jan Šustr, CEO
1st January 2023

Related articles
Related products
286.77 € (tax incl.)
This is Easy Controller for 6-to-2 antenna switch. You can control any antenna switch with 6 inputs. This controller allows you to control antenna switch over the web page.
199.65 € (tax incl.)
This is Easy Controller for antenna stack match with 2 outputs. You can control any stack match with 4 wires. There are 4 combinations: Top, Bottom, Both In Phase and Both Out Phase. Including PTT hot switch...
199.65 € (tax incl.)
This is Easy Controller for 4-to-1 antenna switch. You can control any antenna switch with 4 inputs. Including PTT hot switch protection. You can choose between two versions: classic and remote. Remote version allows...
199.65 € (tax incl.)
This is Easy Controller for antenna stack match with 3 (2) outputs. You can control any stack match with 4 wires. There are 7 combinations. Including PTT hot switch protection. You can choose between two versions:...
199.65 € (tax incl.)
This is Easy Controller for 6-to-1 antenna switch. You can control any antenna switch with 6 inputs. Including PTT hot switch protection. You can choose between two versions: classic and remote. Remote version allows...
Leave a Comment
Leave a Reply
Please login to post a comment.

manuals

Home

Settings

Menu

Create a free account to save loved items.

Sign in

Create a free account to use wishlists.

Sign in