This is high isolation, low loss 6 to 2 RF switch for indoor use.

Read moreShow less
410.19 € (tax incl.)
410.19 €
339.00 € (without tax)
in stock, shipped in 2-3 days

Price history     Price history

The lowest price in the 30 last days was 410.19 €

Brand:
Add to compare0
Love
Add to wishlist
Description

This is the indoor version of the popular RF switch six to two. The indoor version - IND-I - means that it is not waterproof and includes a fan with a dust filter. This version has a redesigned RF PCB with improved parameters. The overall design has been modified so that the switch can be easily disassembled for inspection or repair. The switch consists of an RF PCB, a shielding spacer, and a board with protective FiFo logic, BCD inputs, and RFI filters.

The switch can be used to switch six antennas to two TRX - SO2R, switch filter banks, or switch six TRX to two outputs. The modified version allows a frequency range up to 70 MHz. The control is classic, i.e., 2x6 control wires, or BCD, or a combination of both. In the case of BCD control, a wide range of control voltages can be used.

The protection board also provides FiFo switching – First In, First Out. This means that whoever selects the port first gets to use it, and the second person cannot select it. The protective plate includes an LED indicator for easy control and function monitoring.

The switch includes a fan and dust filters. Since the switch is expected to be placed in an enclosed space where temperatures may be higher, it is recommended not to disconnect the fan. Especially at higher power levels and in digital modes, the relay may heat up.


Using

  • Six port antenna switch
  • One antenna to six TRX
  • You can use two pieces for switching bank of six filters

Main functions

  • Six ports switchable to two inputs/outputs
  • Frequency range DC to 70 MHz
  • Characteristic impedance 50 Ohm
  • High isolation and low insertion loss
  • Power rating DC to 30 MHz
    • 3 kW continue wave
    • 4 kW PEP (SWR < 1:1.7) - tested with OM-4000
    • Power rating 2 kW @ 50 MHz, 1 kW @ 70 MHz
  • Control positive DC 2 x 6, 2 x BCD or combination
  • Hazzard board protection with 2 x 6 and BCD inputs
  • First-Win logic
  • Without DC power the antenna ports are grounded
  • High quality RF PCB thickness 2 mm
  • Fan with dust filters
  • High quality connectors
  • Aluminium shield enclosure
  • AL box size 250x145x100 mm (with connectors)
  • Stainless screws
  • ASSEMBLED and TESTED VERSION

Parameters

  • Frequency range DC to 70 MHz
  • Power rating DC to 30 MHz
    • 3 kW continue wave
    • 4 kW PEP (SWR < 1:1.7) - tested with OM-4000
    • Power rating 2 kW @ 50 MHZ, 1 kW @ 70 MHz
  • High isolation between A and B ports: 100 dB (20 m), >90 dB (10 m) - no port selected
  • High isolation A-1 and B-2: >100 dB (80 m), >84 dB (20 m), > 80 dB (10 m), 75 dB (6 m), 72 dB (4 m)
  • High isolation A-1 and B-6: >100 dB (80 m), >84 dB (20 m), > 83 dB (10 m), 82 dB (6 m), 80 dB (4 m)
  • Insertion loss better than 0.04 dB (10 m), 0.02 dB (20 m)
  • Control DC 2 x 6 wires + 12 to 15 V or image
  • Control BCD + 3 to 15 V (TTL compatible or direct 13 to 15 V BCD) image
  • When the BCD voltage is higher than 13 V, it directly supplies the relay
  • BCD inputs with optocouplers and protections
  • BCD inputs wide range 3 to 15 V DC
  • BCD data format is 1 to 6
  • BCD inputs with positive control compatible with OM-power, Microham. Pull up for open collector - image
  • DC supply voltage is recommended 13.8 V
  • DC supply current up to 0.4 A
  • Fan with lower speed
  • Dust filters

Isolation example

  • TRX A output power 1 kW =1,341 k 60 dBm
  • Isolation to port B is 80 dB → 60 dM - 80 dB = -20 dB
  • ~10 UW at TRX port B

 DO NOT forget to

  • Isolation between antennas!
  • The safe power isolation is not only about the switch isolation!
  • Never switch relay during TX!
  • Use high quality RF connectors and coax cables. The shielding of coaxial cables has a significant impact on insulation and potential interference.

Connection

  • You can use 2 x 6 + GND = 13 wires (12 to 15 V DC)
  • You can use 2 x BCD (TTL) + GND + 13.8 V = 8 wires
  • You can use 2 x BCD (> 13 V) + GND = 7 wires
  • Combination: one port 6 wires, second BCD

 


Available as

ASSEMBLED: ready to use

RECOMMENDATIONS TO BUY:

Included in package

Switch assembled and tested


Manual

If you want to know more please check our wiki with 6-to-2 IND-I manual.



antenna switch 6-2 IND-I classic version qro.cz hamparts.shop

antenna switch 6-2 qro.cz hamparts.shop

antenna swtich 6-2 qro.cz hamparts.shop

Third party software FreqEZ

  FreqEZ is a Do-It-Yourself hardware/software project by Larry K8UT that provides highly configurable Band Decoding and Remote Antenna Selection. For amateurs who use N1MM+ and DXLab logging software, FreqEZ will leverage those programs TCP/UDP broadcasts for antenna switching. For other amateurs, FreqEZ can connect to the BCD band outputs available from most transceivers. The FreqEZ software and is freely available to all hams, and consists o

Read moreShow less
Product Details

Data sheet

type
ASSEMBLED
design
in enclosure
usage
RX + TX
impedance
50 Ohm
front-end protection
none
frequency range
DC to 70 MHz
product dimensions
250x145x100 mm
product weight (brutto)
1.51 kg
package dimensions
27x23x15 cm
Reviews
No comments
You may also like
280.72 € (tax incl.)
232.00 € (without tax)
This is Easy Controller for 6-to-2 antenna switch. You can control any antenna switch with 6 inputs. This controller allows you to control antenna switch over the web page.

manuals

Home

Settings

Menu

Create a free account to save loved items.

Sign in

Create a free account to use wishlists.

Sign in